Low price and easy to use applicable petrochemical JH-RCL-60KWA380-P Adjustable dummy load bank
RCL load is a load that contains resistance, capacitance and inductance in the circuit simultaneously.
Application : 1.Used in power, telecommunications and other departments and manufacturers of online high-power UPS, inverters, switching power supply and diesel generator set performance testing, aging and other occasions
Customization service: Please tell us more detailed requirements, such as product size, total power, voltage, classification method (minimum step size), control method, etc.
- Overview
- Parameter
- Inquiry
- Related Products
Cost-Effective: The JH-RCL-60KWA380-P offers a low price point, making it an economical choice for load testing applications.
User-Friendly Design: With its easy-to-use interface, this load bank simplifies the process of adjusting and managing load levels.
Versatile Application: Designed for petrochemical environments, it can handle a wide range of load testing scenarios, ensuring compatibility with various power systems.
Adjustable Load Levels: The load bank’s adjustable dummy load feature allows precise control over the load applied, making it suitable for different testing requirements.
Product parameter | ||||||||
Model number | JH-RCL-60KWA380-P | |||||||
brand | jianhong | |||||||
dimension | ≤1200*700*1800MM(L*W*H) | |||||||
weight | ≤400KG | |||||||
Rated voltage | AC380V | |||||||
Rated active power | R-load: 60KW L-load: 72VAR C-load:60VAR |
|||||||
Auxiliary power supply | AC220V ~AV250V 50/60HZ | |||||||
Power factor | 0.7-1 | |||||||
Resistance accuracy | ±1%(Sheet resistor) | |||||||
Cold pass | Forced air cooling, front to back, 15050 fans - 24 (220VAC power) | |||||||
Working environment | Working temperature: -10~50℃, dry and ventilated | |||||||
Control mode | Push button control | |||||||
Class of protection | IP20 (indoor) | |||||||
Display mode | Digital display voltage, current, active power, reactive power,real power, power factors, etc | |||||||
Adjustable range | R load: 1W-20kW (single-phase 1W step adjustable) L load: 1var-24Kvar (single-phase 1VAR step adjustable) C load: 1var-20Kvar (single-phase 1VAR step adjustable) |
|||||||
Load protection | Overheat alarm, overvoltage protection, fan failure alarm, emergency stop | |||||||
Working mode | Can work continuously online, 7*24 working system, warranty 1 year | |||||||
Output mode | 1 group of resistance outlets A, B, C, N (bronze) +1 group of auxiliary power supply (TB2504 wiring bar) | |||||||
Mobile mode | castor |