Efficient Energy Recovery: The system captures and harnesses energy during braking, converting it into usable electricity. By feeding this energy back into the grid, it minimizes wastage and enhances overall efficiency.
Cost Savings: Long-term power braking often results in substantial energy dissipation. With the feedback unit, recovered energy offsets the need for additional power generation, leading to cost savings.
Reduced Environmental Impact: By reusing braking energy, the system reduces reliance on fossil fuels and curtails greenhouse gas emissions. It aligns with sustainable practices and contributes to a greener environment.
Enhanced System Stability: The feedback unit stabilizes the power supply by absorbing excess energy during braking. This prevents voltage fluctuations and ensures consistent performance.
Extended Equipment Lifespan: Reduced strain on braking components prolongs their operational life. The system’s energy feedback mechanism mitigates wear and tear, enhancing overall equipment durability.
Technical parameter list
Input voltage | |
network voltage |
3AC220V、3AC380V、3AC660V -15%+10% Or user customized |
network frequency |
50Hz±3Hz |
Dc voltage |
220V、380V:<720V 660V:<1150V |
Voltage harmonics |
≤5% |
Performance characteristics | |
Adaptive power or rated capacity |
220V: 30KW/45KW/75KW/110KWEtc. 380V: 45KW/75KW/110KW/160KW/200KW/250KW/315KW/400KWEtc. 660V: 45KW/75KW/110KW/160KW/200KW/250KW/320KW/400KW/500KWEtc. |
Dcvoltage control |
Feedback function: Operating voltage: > 1.5 times the power grid voltage +50V 220V, 380V: < 720V 660V: < 1150V PWM rectification and SVG features: Stable voltage: > 1.5 times the power grid voltage +50V 220V, 380V: < 720V 660V: < 1150V |
Voltage control accuracy |
≤0.5% |
Power factor |
>0.95 |
Output harmonic content |
<5% |
Overload capacity multiple |
1.45 times 60 seconds; 1.5x protection |
Operating efficiency |
≥97% |
Full response time |
≤10ms |
Input voltage | |
network voltage |
3AC220V、3AC380V、3AC660V -15%+10% Or user customized |
network frequency |
50Hz±3Hz |
Dc voltage |
220V、380V:<720V 660V:<1150V |
Voltage harmonics |
≤5% |
Performance characteristics | |
Adaptive power or rated capacity |
220V: 30KW/45KW/75KW/110KWEtc. 380V: 45KW/75KW/110KW/160KW/200KW/250KW/315KW/400KWEtc. 660V: 45KW/75KW/110KW/160KW/200KW/250KW/320KW/400KW/500KWEtc. |
Dcvoltage control |
Feedback function: Operating voltage: > 1.5 times the power grid voltage +50V 220V, 380V: < 720V 660V: < 1150V PWM rectification and SVG features: Stable voltage: > 1.5 times the power grid voltage +50V 220V, 380V: < 720V 660V: < 1150V |
Voltage control accuracy |
≤0.5% |
Power factor |
>0.95 |
Output harmonic content |
<5% |
Overload capacity multiple |
1.45 times 60 seconds; 1.5x protection |
Operating efficiency |
≥97% |
Full response time |
≤10ms |